Search results for "Left ventricular assist device"
showing 6 items of 6 documents
Destination Therapy with Left Ventricular Assist Devices in Non-transplant Centres: The Time is Right
2020
For almost half a century, cardiac transplant has been the only long-term treatment for patients with end-stage heart failure. Implantable left ventricular assist devices (LVADs) have emerged as a new treatment option for advanced heart failure as destination therapy for patients either too old or not suitable for transplant. A meta-analysis presenting head-to-head comparisons of cardiac transplant versus LVAD as destination therapy (LVAD-DT) found no difference in 1-year mortality rates between LVAD-DT and cardiac transplant (OR 1.49; 95% CI [0.48–4.66]; I2=82.8%). Moreover, a recent subanalysis from the Interagency Registry for Mechanically Assisted Circulatory Support found similar outco…
Shear stress alterations in the celiac trunk of patients with a continuous-flow left ventricular assist device as shown by in-silico and in-vitro flo…
2017
Background The use of left ventricular assist devices (LVADs) to treat advanced cardiac heart failure is constantly increasing, although this device leads to high risk for gastrointestinal bleeding. Methods Using in-silico flow analysis, we quantified hemodynamic alterations due to continuous-flow LVAD (HeartWare, Inc., Framingham, MA) in the celiac trunk and major branches of the abdominal aorta, and then explored the relationship between wall shear stress (WSS) and celiac trunk orientation. To assess outflow from the aortic branch, a 3-dimensional-printed patient-specific model of the celiac trunk reconstructed from an LVAD-supported patient was used to estimate echocardiographic outflow …
Particle image velocimetry study of the celiac trunk hemodynamic induced by continuous-flow left ventricular assist device
2017
Abstract Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the disease mechanisms. Here we present an experimentally-calibrated computational model of the celiac trunk hemodynamic of a LVAD-supported patient who experienced bleeding after device implantation. Specifically, both particle image velocimetry (PIV) and echocardiography were used to measure and compare flow distributions in each branch of a phantom model of the patient abdomi…
Early cardiac unloading with ImpellaCP™ in acute myocardial infarction with ventricular septal defect
2020
Abstract Despite a relative contraindication, mechanical support with Impella™ left ventricular assist device has already been described for ischaemic ventricular septal defect treatment, either as a bridge to surgery, as intraoperative mechanical haemodynamic support, or to ensure intraprocedural haemodynamic stability during device closure. We describe two cases of ventricular septal defect complicating acute myocardial infarction, where the percutaneous ImpellaCP was implanted early (differently than previously described) with the aim of preventing haemodynamic instability, while deferring surgical repair. We present a report of haemodynamic, echocardiographic, biochemical, and clinical …
Relationship between device acceptance and patient-reported outcomes in Left Ventricular Assist Device (LVAD) recipients
2019
AbstractThe number of Left Ventricular Assist Devices (LVADs) implanted each year is rising. Nevertheless, there are minimal data on device acceptance after LVAD implant, and on its relationship with patient-reported outcomes. We designed a cross-sectional study to address this knowledge gap and test the hypothesis that low device acceptance is associated with poorer quality of life, depression and anxiety. Self-report questionnaires were administered to assess quality of life (12-item Kansas City Cardiomyopathy Questionnaire quality of life subscale), level of anxiety (7-item Generalized Anxiety Disorder; GAD-7), level of depression (9-item Patient Health Questionnaire; PHQ-9) and device a…
Modeling Right Ventricle Failure After Continuous Flow Left Ventricular Assist Device: A Biventricular Finite-Element and Lumped-Parameter Analysis
2017
The risk of right ventricle (RV) failure remains a major contraindication for continuous-flow left ventricular assist device (CF-LVAD) implantation in patients with heart failure. It is therefore critical to identify the patients who will benefit from early intervention to avoid adverse outcomes. We sought to advance the computational modeling description of the mechanisms underlying RV failure in LVAD-supported patients. RV failure was studied by computational modeling of hemodynamic and cardiac mechanics using lumped-parameter and biventricular finite element (FE) analysis. Findings were validated by comparison of bi-dimensional speckle-tracking echocardiographic strain assessment of the …